VSM Vacuum Transducer ● Pirani/Cold Cathode ● 1000 to 5e-9 mbar ● digital
€ 1,140.00 – € 1,528.00 excl. VAT and transport costs
The digital combination transducer VSM (Pirani/cold cathode) measures absolute pressure from atmospheric pressure to ultrahigh vacuum.
The digital combination transducer VSM (Pirani/cold cathode) measures absolute pressure from atmospheric pressure to ultrahigh vacuum.
Overview Smartline vacuum transducers:
- Variety of interfaces: Digital RS485 interfaces plus 0-10 V output signal, EtherCAT or PROFINET. The Bluetooth adapter SLKBT enables wireless communication
- Industry 4.0: All Smartline transducers offer a series of parameters for preventive maintenance. PROFINET transducers are able to communicate with OPC UA servers and support MRP
- Exchangeable sensor heads: Is an easy job, independent of the gauge manufacturer and without programming effort. If the existing cables shall further be used, suitable adapters (e. g. FCC68) will be available.
- Optional display: Large LCD display (exc. EtherCAT, PROFINET)
- Easy adjustment: Readjustment of zero and atmosphere by push-button or interface
- LEDs: For device status and switch points
- Scaleable output characteristics: The 0-10 V output signal can be scaled according to the required output characteristics. Thus an exchange of existing vacuum gauges is easily, independent of the manufacturer and without programming effort possible. If the cable needs to remain but the transducer should be changed adapters (e. g. FCC68) are available.
- UHV suitable: Metal sealed stainless steel sensor cell,suitable for UHV applications (He leackage rate <5e-10 mbar l / s)
- Relay switch points: Two independent, potentialfree relay switch points (exc. EtherCAT, PROFINET)
- Robust: Resistant, EMC compatible metal housing, protection class up to IP54
- Controller: Expansion with 2 channel controller VD12 or 4 channel controler VD14 possible
- VacuGraphTM software: For visualisation, analysis and storage of measuring data
Overview VSM vacuum transducer with Pirani /cold cathode sensor:
- Wide measuring range: Wide range combi sensor Pirani / cold cathode
- Long-living: Automatic control of the cold cathode by the Pirani, switch-on of cold cathode at low pressure increases lifetime, insensitive against inrush of air
- Reliable: Excellent ignition behavior
- Low stray magnetic field
- Overpressure stable: Overpressure stability up to 16 bar
Do you have questions regarding our VSM vacuum transducers with Pirani/cold cathode sensor? We will be pleased to assist.
Attention: If the Smartline transducer is used without PLC, an SLN4 power supply will be required.
→ Go to all transducers of the Smartline | → Go to accessories for all Smartline vacuum transducers
Weight | 1.1 kg |
---|---|
Dimensions | 25 × 16 × 9 cm |
Measurement principle | |
Gas dependency | depending on gas type |
Measurement range mbar | |
Measurement range Torr | 750 – 5e-9 Torr |
max. overload | 10 bar abs., 16 bar abs. with CERT31P |
max. overload with CERT31P | up to 16 bar abs. |
Accuracy | 1000 – 10 mbar: approx. 30 % f. r. | 10 – 2e-3 mbar: 10 % f. r. | 2e-3 – 1e-8 mbar: 25 % f. r. |
Repeatability | 10 – 1e-2 mbar: ca. 2% f. r. | 1e-2 – 1e-8 mbar: ca. 7% f. r. |
Materials in contact with vacuum | Stainless steel 1.4307, tungsten, nickel, glass, molybdenum, Al₂O₃ ceramic |
Filaments / anodes | Molybdenium |
anode voltage | < 2.5 kV |
Response time | 50 ms (switch-on cold cathode <2s) |
Operating temperature | +5…+60 °C |
Storage temperature | -40…+65 °C |
Bake out temperature | |
Voltage supply | 20 – 30 VDC |
Power consumption | Max. 3 W, add. 0.8 W for EtherCAT / relays /LCD, 1.6 W for Profinet |
Output Signal SL | 0 – 10 VDC, min. 10 kΩ, measuring range 1,82 – 8,6 VDC, log. (Default) except EtherCAT, Profinet |
Serial interface | RS485: 9.6 kBd to 115 kBd, 8 databit, 1 stopbit, no parity, EtherCAT, Profinet |
Electrical connection | RS485/0-10V: SubD, 15-pole, male | RS485/EtherCAT/Profinet: 1x M12 A / 2x M12 D, female |
Vacuum connection | DN 25 ISO-KF (VSM77), DN 40 ISO-KF (VSM78), DN 40 CF-F (VSM79) |
Protection class | |
Certification | CSA, UL (cCSAus) |
Dimensions | 139 x 69 x 48 mm (VSM77) |
Weight | 555 g (VSM77) |
Smartline - product brochure | |
VacuGraph software (free Lite-Version) | |
Data sheets, manuals, 3D models and more |
How can I set parameters like switching points or gas type correction factors? The Smartline vacuum transducers are programmed via their RS485 interface. They respond e. g. on type requests, measurement requests, adjustment commands and commands forsetting gas type correction factors. It is also possible to program both relay switching points of the gauge via RS485. |
Is the measuring signal independent of the gas type within the rough vacuum range? Yes, in the pressure range above 15 mbar. |
Is the Pirani sensor protected against pollution and dirt? All Thyracont Pirani sensors are fitted with a cover which protects against basic condensation and pollution. If the sensors are used in an extremely polluted environment, it is advised to additionally either use an extension pipe, an elbow fitting, a cooling trap or a seal ring with a sinter filter. We recommend keeping the transducer switched on permanently, as a hot Pirani filament is less susceptible to contamination. |
Is it possible to clean the Pirani sensor? Depending on the type and intensity of the pollution, it is feasible to clean the sensor with isopropanol. To do so, you need to fill the measuring cell completely with isopropanol and let it rest for a few minutes. After removing the fluid, the measuring must dry out completely. Please note that if e.g. oil debris is baked onto the filament, it is very difficult or even impossible to clean. |
Do I have to mount the instrument in a specific position? In principle, the devices can be installed in any position. You will achieve the most accurate measurement results if the flange of the device is horizontal, as the devices have been calibrated in this position. Mounting the sensor from below is not recommended, as condensation and dirt can collect in the measuring cell. |
How often do I need to recalibrate the vacuum transducer? The period between calibrations depends on the specific application. In particular, deposits and dirt in the sensor, but also use under extreme temperature conditions, can make readjustment necessary. For quality assurance, we recommend sending the devices in for calibration every one or two years. We offer a factory calibration (article no. ADJCERT) or a DAkkS calibration (article no. DKDCERT). |
How can I change the sensor heads of the transducers? The replaceable, pre-adjusted sensor heads of the Smartline transmitters can be replaced quickly and easily by the user to ensure consistently high system availability. To do this, the fixing screws of the sensor head are loosened, the sensor unit replaced and the screws refastened. After a warm-up time of approx. 15 minutes, press the Adjust button. The sensors and electronics are now automatically adjusted to each other and the transmitter is ready for operation. |
When to use a hot cathode and when to use a cold cathode? Hot cathode transducers are mainly used for measurements where high precision (<15%) is required. We also recommend our hot cathode for measurements in the ultra-high-vacuum range down to 5e-10 mbar. Cold cathode transducers are more robust in numerous applications and therefore particularly interesting for applications where the sensor is exposed to dust, oil or other pollution. The cold cathode measuring cell can be patrially dismantled and cleaned (e.g. with Scotch Brite). Compared to the VSH, the VSM has a lower, but for a cold cathode very good accuracy of <25%. To ensure high system availability, the sensor head of both transmitters can be easily replaced if necessary. |
Is it possible to clean the sensor head of the VSM? Yes, it is possible to partly dismantle the sensor head and to carefully clean it with Scotch Brite. Thereby, metallic debris and minor pollution can be easily removed. |
Is it possible to clean the sensor head of the VSH? Hot cathode sensors are not suited for cleaning. |
Related products
-
Compare
VD81 Compact Vacuum Meter ● Piezo ● 1600 to 1 mbar
€ 435.00 excl. VAT and transport costs View Product -
Compare
P_VD122 ● Set VD12 with VSC43MV ● 1400 to 1 mbar
€ 1,305.00 excl. VAT and transport costs View Product -
Compare
SP3 Vacuum Transducer ● Pirani ● 1000 to 1e-4 mbar ● analog ● FCC68
€ 338.00 – € 362.00 excl. VAT and transport costs View Product -
Compare
VSR Vacuum Transducer ● Piezo/Pirani ● 1200 to 1e-4 mbar ● digital
€ 607.00 – € 949.00 excl. VAT and transport costs View Product This product has multiple variants. The options may be chosen on the product page
Further relevant products
-
DCERTHV Works Calibration digital ● High Vacuum
€ 221.00 excl. VAT and transport costs View Product -
B_VSM replacement sensor ● Pirani/ Cold Cathode ● for Smartline VSM
€ 327.00 – € 381.00 excl. VAT and transport costs View Product -
Compare
P_VD1277 ● Set VD12 with VSM77D ● Pirani/Cold Cathode ● 1000 to 5e-9 mbar
€ 2,130.00 excl. VAT and transport costs View Product